Fire Detection Alarm System






Fire alarm system are designed to detect early signs of fire inside buildings, especially in high-rise and neutral buildings. The system includes various components such as fire alarm sensor, fire alarm annunciator, and emergency fire alarms to enhance safety measures.
With an intelligent fire alarm system, building security teams can quickly locate the affected area with precision. The integration of fire alarm and sprinkler system, including fire alarm sprinkler system, ensures that fires can be extinguished efficiently. In addition, installing ceiling fire alarm and wireless fire alarm system provides reliable protection while meeting NFPA fire alarm standards. This allows for faster evacuation and extinguishing processes, minimizing potential damage and risks.
Fire Alarm Supplier and Contractor: Complete Fire Alarm System Solutions
As a trusted fire alarm system suppliers and contractors, we provide high-quality fire safety products and expert fire alarm installation services to ensure buildings meet safety regulations.
Our team specializes in fire alarm system installations, ensuring all components are properly integrated for maximum protection in businesses, industrial facilities, and residential properties.
Whether you need a new fire alarm system installation, upgrade, or maintenance, our experienced professionals will provide a reliable solution tailored to your needs.




Addressable Fire Alarm System Control Panel

Specifications
- A single Class A or Class B intelligent device loop is standard, with an optional loop expanding the capacity of the addressable fire alarm control panel (FACP fire alarm) to up to 1,000 devices.
- A 24-line, 40-character backlit LCD capable of displaying eight events simultaneously for enhanced monitoring in addressable fire alarm system.
- Optional voice evacuation and fire department telephone for enhanced emergency communications.
- Part of a comprehensive audio solution suitable for low-frequency signals in sleeping areas, fully compatible with addressable fire alarm system.
- An optional network interface slot is located on the rear of the swing-out mounting chassis, allowing seamless integration with addressable control panels.
- Electronic addressing with automatic device mapping simplifies installation and device recognition within the addressable fire control panel.
- An optional Ethernet port for diagnostics and programming enhances system accessibility and remote configuration.
- Supports strobe synchronization to enhance visual warning in emergency situations.
- Supports up to 30 R-Series remote anunciators with Class A or Class B wiring, ensuring comprehensive coverage within an addressable fire panel.
- Patented Voltage Boost™ technology provides constant voltage to the NAC and AUX circuits – even at low battery levels, increasing the reliability of the addressable fire alarm panel.
- UL-listed 10 Amp power supply with universal 94 to 264 Vac input voltage for worldwide compatibility.
- Integrated Carbon Monoxide gas sensing with V-PCOS detector, featuring a distinctive audible signal for added safety.
- Four built-in Announcement Circuits for efficient alarm signaling.
- Space for three optional front panel LED/Switch modules, enhancing system control within an addressable fire alarm control panel.
- Optional Ethernet interface for advanced networking capabilities.
- UL2572; UL864 UUKL; UL 864 Listed for release applications using GSA-REL, ensuring compliance with industry standards for addressable fire alarm system. Optional seismic hardening with a seismic Importance Factor of 1.5, ensuring durability and stability in critical installations.
Fire Detector

Specifications
- Next-generation fire detection system with advanced sensing technology.
- Integrates optical fire detector sensor with carbon monoxide detection for enhanced safety.
- Wide smoke obscuration of 0.53 to 3.94%/ft (1.7 to 12.35%/m), ensuring accurate smoke detector performance.
- Sensor markings facilitate test identification, improving maintenance of fire detection alarm systems.
- Utilizes existing wiring for seamless integration into fire detection and alarm system.
- Automatic device mapping simplifies setup and improves efficiency of wireless fire detection systems.
- Ground fault detection with module ensures reliable operation in fire and gas detection systems.
- Supports up to 250 total addresses per loop, making it ideal for large-scale fire detection system deployments.
- Two levels of environmental compensation for optimized fire alarm detector performance.
- Two levels of dirty detector warning to maintain accuracy in fire detector operation.
- Up to twenty pre-alarm settings for early warning in fire detection and alarm systems.
- Five sensitivity settings for adjustable fire detection sensor response in various environments.
- Non-volatile memory stores critical system settings, ensuring consistent operation of the intelligent fire detector.
- Electronic addressing allows easy configuration and scalability of the fire detection alarm system.
- Environmental compensation to adapt to changing conditions and improve photoelectric fire alarm accuracy.
- Automatic day/night sensitivity
Fire Alarm Bells

Specifications
- The fire alarm bell is available in vibrating and single-step models for reliable signaling.
- Offered in 6-inch (150 mm), 8-inch (200 mm), and 10-inch (250 mm) fire bell sizes to suit different installation needs.
- Available in red or gray to match a variety of fire alarm bell system aesthetics.
- Rugged and compact mechanism ensures durability in harsh environments.
- Heavy-duty cast housing provides durable protection for the fire alarm bell.
- Low power drain for energy-efficient operation in any fire bell system.
- Wide voltage selection for flexible compatibility with a variety of fire bell alarm setups.
- Suitable for indoor applications and weatherproof, enhancing the versatility of the fire alarm bell.
Fire Alarm System : Horn and Strobe

Specifications
- Unique low-profile design enhances the aesthetics of your fire alarm system strobe light while ensuring reliable performance.
- The most compact UL-1971/ULC-S526 listed fire alarm strobe light available for efficient emergency signaling.
- Ultra-thin design protrudes less than an inch, making it an ideal choice for modern alarm strobe lights.
- Attractive appearance with no visible mounting screws for seamless integration into fire alarm horn and strobe systems.
- Selectable 15, 30, 75, or 110 cd fire alarm strobe light output to meet a variety of safety requirements.
- Adjustable high (default) or low dB fire alarm horn output for customizable warnings.
- Choose between temporary (default) or fixed fire alarm horn output to suit different alarm settings.
- Public mode flash rate (default) or private mode temporal flash for flexible alarm light operation.
- Fixed 15/75 cd models available, ensuring compliance with fire safety regulations.
- ECS/MNS models available to support mass notification and emergency communications.
- Easy to install and fits into standard 1-gang electrical boxes – no trim plates required for quick setup of fire alarm horns and strobes.
- Optional trim plates accommodate large openings, providing a clean installation for fire alarm system strobes.
- Pre-assembled with anchoring hardware for hassle-free installation.
- #12 AWG terminals – ideal for long runs or existing wiring
- Unmatched performance
- Most even light distribution in the industry
- Meets tough synchronization standards for strobes
- Single microprocessor controls horn and strobe
- Independent horn control via one pair of wires
- Fine-tuned high currents
- Multiple frequency tones enhance sound penetration
- Field-programmable temporal strobe output option
Manual Pull Station

Specifications
- Fire alarm pull station with pull lever for fast and efficient activation.
- Simple and positive operation ensures ease of use in emergency situations in fire alarm system pull station settings.
- Integrated glass break feature enhances safety and reliability in manual fire pull station operation.
- Attractive and sleek design blends seamlessly with modern fire pull stations.
- Requires less than 5 lbs of pull force, meets ADA standards for accessible manual pull station fire alarm system activation.
- Rugged cast metal construction provides durability and long-lasting performance for reliable alarm pull station.